Aminex Organic Acid and Alcohol Analysis Columns
| Brand | Bio-Rad |
| Application | Organic acid analysis, Alcohol analysis |
| Package | 1/Pkg |
| Synonyms | HPLC, 유기산분석, Organic acid analysis, 알콜분석, 알코올분석, Alcohol analysis, Prepack column, Pre-packed column, HPLC column, Aminex column |
Features
Aminex HPLC columns are packed with a polymer-based matrix (polystyrene divinylbenzene). They separate compounds using the ion-moderated partition chromatography technique.
HPLC separations using Aminex columns employ the mechanisms of ion exclusion, ion exchange, ligand exchange, size exclusion, reversed phase, and normal phase partitioning. These multiple modes of interaction offer a unique ability to separate compounds. Several Aminex columns are available for small acidic and polar molecule analysis.
Aminex columns allow the use of simple isocratic methods, eluting with water or dilute acid. There is minimal sample preparation, usually just filtering through a 0.45 μm filter with no derivatization necessary. Aminex media have a high pressure stability, wide pH stability, and high column efficiency and selectivity.
Aminex columns are an industry standard for the analysis of organic acids and alcohols. Bio-Rad offers organic acid columns for simple, yet specific methods of food and beverage analysis. Use the selection guide below to choose the column that fits your application needs.
Aminex HPX-87H Column
This hydrogen-form, 300 x 7.8 mm column performs most analyses in about 20 minutes, with sensitivity to the nanogram level. A simple isocratic elution with slightly acidified water is all that it takes to analyze organic acids in most samples, and filtration is the only sample preparation required before injection. Separations can be performed from ambient temperature to 60°C at flow rates of 0.4–1.0 ml/min. When many compounds in a formulation must be analyzed, or when high-resolution separations are required, this is the column of choice.
Fast Acid Analysis Column
This hydrogen-form, 100 x 7.8 mm column is optimized for the analysis of alcohols, glycols, and hydrophobic organic acids. Typically, analyses can be shortened 4-fold over those obtained with research-length columns. Because the fast acid column is shorter, components elute as taller, narrower peaks. Detection limits are improved, and smaller sample loads can be used. This column provides fast separations of specific organic acids in samples where only certain components are of interest. With these columns, analyses can be completed in 3–5 minutes. As with the Aminex HPX-87H column, dilute sulfuric acid is the only eluent used, and filtering is generally the only sample preparation required.
Fermentation Monitoring Column
This hydrogen-form, 150 x 7.8 mm column is optimized to resolve maltotriose, maltose, glucose, and fructose while also resolving acids and alcohols. When analysis of sugars in a fermentation broth is required, this is the column of choice. Dilute sulfuric acid is the only eluent used, and filtering is generally the only sample preparation required.
Aminex HPX-87C Column
This calcium-form, 300 x 7.8 mm column can be fine-tuned for organic acid analysis by using an eluent that contains a mixture of water, calcium sulfate, sulfuric acid, and acetonitrile. It is also suited for analyzing organic acids in combination with carbohydrates.
Peaks: 1 Maltotriose, 2 Maltose, 3 Citric acid, 4 Tartaric acid, 5 Glucose, 6 Fructose, 7 Succinic acid, 8 Lactic acid, 9 Glycerol, 10 Acetic acid, 11 Pyroglutamic acid, 12 Methanol, 13 Ethanol
Aminex HPX-87H Column
Fermentation standard separated on the Aminex HPX-87H column.
Column: Aminex HPX-87H column, 300 × 7.8 mm
Sample: Fermentation standards
Eluant: 5 mM sulfuric acid
Flow rate: 0.60 mL/min
Temperature: 50℃
Detection: UV 210 nm, RI
Selection Guide and Specifications
| Phases Available | Applications | Description | Column |
|---|---|---|---|
| Monosaccharide | * Column of choice for monosaccharides and sugar alcohols from sweeteners, corn, and cane sugars * For class separation of di-, tri-, and tetrasaccharides * Primarily used for the quantitation of glucose and fructose, and for general monosaccharide analysis | 8% cross-linked resin Calcium ionic form Particle size: 9 μm pH range: 5-9 Column size: 300 × 7.8 mm | Cat. No. 125-0095Aminex HPX-87C |
| Monosaccharide | * For analysis of carbohydrates found in solution with carboxylic acids, volatile fatty acids, short chain fatty acids, alcohols, ketones, and many neutral metabolic by-products * Most commonly used for organic acid analysis, fermentation monitoring, biological fluid analysis, acetylated amino sugar separations, and quantification of biomass to biofuels analysis | 8% cross-linked resin Hydrogen ionic form Particle size: 9 μm pH range: 1-3 Column size: 300 × 7.8 mm | Cat. No. 125-0140Aminex HPX-87H |
| Monosaccharide | * Monosaccharides and sugar alcohol analysis * Tailored for the separation of cellulose-derived monosaccharides * For analysis of pentoses and hexoses in wood products, especially cellobiose, glucose, xylose, galactose, arabinose, and mannose * Excellent resolution of sucrose, lactose, and fructose in dairy products | 8% cross-linked resin Lead ionic form Particle size: 9 μm pH range: 5-9 Column size: 300 × 7.8 mm | Cat. No. 125-0098Aminex HPX-87P |
| Mono-, di-, and oligosaccharides | HPLC carbohydrate analysis column: * Optimized for analysis of mono- and disaccharides in starch hydrolysates * Provides high-resolution separations of oligosaccharides as large as DP-10 | 4% cross-linked resin Calcium ionic form Particle size: 25 μm pH range: 5-9 Column size: 300 × 7.8 mm | Cat. No. 125-0096Aminex HPX-42C |
| Mono-, di-, and oligosaccharides | HPLC carbohydrate analysis column: * For fast, high-resolution oligosaccharides analysis * Separates oligosaccharides as large as DP-11 in 25 minutes | 4% cross-linked resin Silver ionic form Particle size: 25 μm pH range: 6-8 Column size: 300 × 7.8 mm | Cat. No. 125-0097Aminex HPX-42A |
| Mono-, di-, and oligosaccharides | HPLC carbohydrate analysis column: * Optimized for analysis of mono-, di-, and trisaccharides in samples such as corn sytup, brewing wort * High-quality separations of glucose, maltose, and maltotriose | 8% cross-linked resin Potassium ionic form Particle size: 9 μm pH range: 5-9 Column size: 300 × 7.8 mm | Cat. No. 125-0142Aminex HPX-87K |
| Organic acid | * Separation of organic acids alone or in combination with carbohydrates, alcohols, fatty acids or neutral compounds; separation of amino sugars * Analysis time: 20 minutes for most analyses * Sensitivity: nanogram level * Separation conditions: from ambient temperature to 60℃; flow rates of 0.4 to 1.0 mL/min * Column of choice when many compounds in a formulation must be analyzed or when high-resolution separations are required | 8% cross-linked resin Hydrogen ionic form Particle size: 9 μm pH range: 1-3 Column size: 300 × 7.8 mm | Cat. No. 125-0140 Aminex HPX-87H |
| Organic acid and alcohol | HPLC organic acid and alcohol column: * Optimized to resolve maltotriose, maltose, glucose, and fructose while separating acids and alcohols * Column of choice when analyzing sugars in a fermentation broth | 8% cross-linked resin Hydrogen ionic form Particle size: 9 μm pH range: 1-3 Column size: 150 × 7.8 mm | Cat. No. 125-0115 Fermentation monitoring |
| Fast carbohydrate | HPLC carbohydrate analysis column: * Designed for extremely fast separations of specific carbohydrates * Optimized for 5-minute analyses of sucrose, glucose, galactose, and fructose | 8% cross-linked resin Lead ionic form Particle size: 9 μm pH range: 5-9 Column size: 100 × 7.8 mm | Cat. No. 125-0105Fast carbohydrate analysis |
| Fast acid, organic acid, and alcohol | HPLC organic acid and alcohol column: * Optimized for analysis of alcohols, glycols, and hydrophobic organic acids; rapid screening of fruit quality * Analysis time: decreased fourfold when compared to research-length columns; analyses can be completed in 3-5 minutes * Quality results: shorter column results in taller, narrower peaks with improved detection limits and smaller sample load requirements * Provides fast separations of specific organic acids | 8% cross-linked resin Hydrogen ionic form Particle size: 9 μm pH range: 1-3 Column size: 100 × 7.8 mm | Cat. No. 125-0100 Fast acid analysis |
| Sugar analysis with high salt concentrations | * Optimized for sugar analysis in samples with high salt concentrations such as beet sugars and molasses * Compatible with salts, no need for desalting prior to analysis | 8% cross-linked resin Sodium ionic form Particle size: 9 μm pH range: 5-9 Column size: 300 × 7.8 mm | Cat. No. 125-0143 Aminex HPX-87N |
| Sugar alcohols and organic acids with carbohydrates | * For sugar analysis according to USP procedures * Appropriate for sugar alcohol separations and can be fine-tuned for organic acid analysis * For analyzing organic acids in combination with cabohydrates | 8% cross-linked resin Calcium ionic form Particle size: 9 μm pH range: 5-9 Column size: 250 × 4.0 mm | Cat. No. 125-0094 Sugar alcohol analysis Aminex HPX-87C |
Ordering Info
| Cat. No. | Product | Unit |
|---|---|---|
| 125-0140 | Aminex HPX-87H Column | 1/pkg |
| 125-0100 | Fast Acid Analysis HPLC Column | 1/pkg |
| 125-0115 | Fermentation Monitoring Column | 1/pkg |
| 125-0095 | Aminex HPX-87C Column (300 × 7.8 mm) | 1/pkg |
| 125-0118 | Micro-Guard De-Ashing Refill Cartridges | 2/pkg |
| 125-0119 | Micro-Guard Carbo-P Refill Cartridges | 2/pkg |
| 125-0128 | Micro-Guard Carbo-C Refill Cartridges | 2/pkg |
| 125-0129 | Micro-Guard Cation H Refill Cartridges | 2/pkg |
| 125-0506 | Micro-Guard Anion CO₃⁻ Cartridges | 2/pkg |
| 125-0508 | Micro-Guard Cation Na⁺ Cartridges | 2/pkg |
| 125-0131 | Standard Cartridge Holder for HPLC Systems | 1/pkg |
| 125-0147 | Cartridge Holder Seal Replacement Kit | 1 set |
| 125-0148 | Cartridge Holder Seals | 2/pkg |
| 125-0139 | De-Ashing Cartridge Holder | 1/pkg |